Comparative study between absorbable and non absorbable plates in management of zygomatic complex fractures. Hamed EL-Sherbiny - Mohamed Ali El-Saied – Yasser Haroun Mohamed and Hatem El-Mekkawi*. ENT Department-Benha Faculty of medicine - Zagazig university Maxillofacial department – Nasser institute Hospital and research center – Cairo*.
• 2004
Publication Information
Authors
Not Available
Keywords
Not Available
Journal
Not Available
Publisher
Not Available
Volume
Not Available
Issue
Not Available
Pages
Not Available
publication.type
Local
Paper Link
Not Available
Supplementary Materials
Not Available
Abstract
البحث الخامس
دراسة مقارنة بين الشرائح الممتصة و غير الممتصة لتثبيت كسور عظام الوجنة.
بحث مشترك منشور في مجلة الزقازيق الطبية.
المجلد 10 العدد 2 مارس 2004
Comparative study between absorbable and non absorbable plates in management of zygomatic complex fractures.
Hamed EL-Sherbiny - Mohamed Ali El-Saied – Yasser Haroun Mohamed and Hatem El-Mekkawi*.
ENT Department-Benha Faculty of medicine - Zagazig university
Maxillofacial department – Nasser institute Hospital and research center – Cairo*.
Abstract:
The aim of this pilot study was to assess the efficiency, pliability, contouring, memory and resistance to infection of absorbable plates in fixing reduced zygomatic complex fractures (ZCF). This study included 30 patients with ZCF, 15 patients (first group)fixed by absorbable plates and 15 patients (second group) fixed by titanium plates. Post-operative infection and residual neurological deficit occur only in second group, whereas some complications e.g ectropion occur more in second group. Absorbable plates and screws may come to represent the standard of care in management of ZCF than the titanium plates and screws due to many advantages as ease of application, no adverse reaction at the implantation sites, patient awareness of the plates was limited and very transient. Radiological scattered artifacts were avoided and avoidance of another operation to remove the plates with all hazards of surgery.
دراسة مقارنة بين الشرائح الممتصة و غير الممتصة لتثبيت كسور عظام الوجنة.
بحث مشترك منشور في مجلة الزقازيق الطبية.
المجلد 10 العدد 2 مارس 2004
Comparative study between absorbable and non absorbable plates in management of zygomatic complex fractures.
Hamed EL-Sherbiny - Mohamed Ali El-Saied – Yasser Haroun Mohamed and Hatem El-Mekkawi*.
ENT Department-Benha Faculty of medicine - Zagazig university
Maxillofacial department – Nasser institute Hospital and research center – Cairo*.
Abstract:
The aim of this pilot study was to assess the efficiency, pliability, contouring, memory and resistance to infection of absorbable plates in fixing reduced zygomatic complex fractures (ZCF). This study included 30 patients with ZCF, 15 patients (first group)fixed by absorbable plates and 15 patients (second group) fixed by titanium plates. Post-operative infection and residual neurological deficit occur only in second group, whereas some complications e.g ectropion occur more in second group. Absorbable plates and screws may come to represent the standard of care in management of ZCF than the titanium plates and screws due to many advantages as ease of application, no adverse reaction at the implantation sites, patient awareness of the plates was limited and very transient. Radiological scattered artifacts were avoided and avoidance of another operation to remove the plates with all hazards of surgery.