The Correlation between the Plasma Level of NT-Pro BNP and Left Ventricular Diastolic Dysfunction
• 2016
Publication Information
Authors
Osama Sanad Arafa1, Mohamed Ahmed Hamouda2, Mohamed Abd El-Kader Elian3, Shaimaa Ahmed Mostafa3*, Mahmoud Said Mahmoud4
Keywords
Not Available
Journal
Not Available
Publisher
Not Available
Volume
Not Available
Issue
Not Available
Pages
Not Available
publication.type
International
Paper Link
Not Available
Supplementary Materials
Not Available
Abstract
Objective: To study the correlation between plasma level of N-terminal pro-BNP and left ventricular diastolic dysfunction
in asymptomatic patients.
Methods: The study included 35 patients divided into control group: included 10 patients with normal systolic and diastolic
function and patient group: included 25 patients with normal systolic and asymptomatic diastolic dysfunction. The patients
were evaluated by conventional echocardiography (diameters, systolic and diastolic function) and tissue Doppler (early
diastolic velocity) then E/e` was measured. Serum pro BNP was measured and correlated with demographic and echocardiographic
parameters and its sensitivity, specificity were evaluated.
Results: Both groups were of comparable age, gender, BMI, risk factors and systolic function. By Doppler echocardiography
there was no difference in E velocity between two groups (0.64+0.18 m/sec Vs 0.67+0.14 P = 0.302), but by tissue
Doppler there was significant difference in the mean value of e` velocity (m/sec) (0.14+0.06 Vs 0.06+0.01 P=0.001) and
E/eˋ (5.03+0.149 Vs 0.55+1.79 P= 0.001). There was significant difference between two groups according to serum NT
pro BNP (ng/ml) was (59.1) in the control group Vs (154.1) in patient group (P = 0.001). There was significant correlation
between serum NT pro BNP and E (P= 0.001) and E/e` (P = 0.001). The sensitivity of serum NT Pro BNP was 94.2,
specificity was 88.1, positive predictive value was 90.6 and its accuracy was 86.2.
Conclusion: Serum level of NT pro BNP can be used as innovative method in predicting asymptomatic diastolic dysfunction
and so prevent the progression to symptomatic diastolic heart failure.
in asymptomatic patients.
Methods: The study included 35 patients divided into control group: included 10 patients with normal systolic and diastolic
function and patient group: included 25 patients with normal systolic and asymptomatic diastolic dysfunction. The patients
were evaluated by conventional echocardiography (diameters, systolic and diastolic function) and tissue Doppler (early
diastolic velocity) then E/e` was measured. Serum pro BNP was measured and correlated with demographic and echocardiographic
parameters and its sensitivity, specificity were evaluated.
Results: Both groups were of comparable age, gender, BMI, risk factors and systolic function. By Doppler echocardiography
there was no difference in E velocity between two groups (0.64+0.18 m/sec Vs 0.67+0.14 P = 0.302), but by tissue
Doppler there was significant difference in the mean value of e` velocity (m/sec) (0.14+0.06 Vs 0.06+0.01 P=0.001) and
E/eˋ (5.03+0.149 Vs 0.55+1.79 P= 0.001). There was significant difference between two groups according to serum NT
pro BNP (ng/ml) was (59.1) in the control group Vs (154.1) in patient group (P = 0.001). There was significant correlation
between serum NT pro BNP and E (P= 0.001) and E/e` (P = 0.001). The sensitivity of serum NT Pro BNP was 94.2,
specificity was 88.1, positive predictive value was 90.6 and its accuracy was 86.2.
Conclusion: Serum level of NT pro BNP can be used as innovative method in predicting asymptomatic diastolic dysfunction
and so prevent the progression to symptomatic diastolic heart failure.
Staff Members - Benha University