Banner

“Onset Voltage Of Negative Corona On Dielectric-Coated Electrodes In Air” Published in Journal of physics D: Applied Physics, vol. 38 ,pp. 3403–3411

• 2005
العودة
معلومات البحث
المؤلفون Not Available
الكلمات المفتاحية Not Available
المجلة العلمية Not Available
الناشر Not Available
المجلد Not Available
العدد Not Available
الصفحات Not Available
publication.type International
رابط البحث Not Available
المواد المرفقة Not Available
الملخص
This paper describes theoretical and experimental investigations of the effect of an electrode coating on the onset voltage of a corona on negatively stressed electrodes. Dielectric-coated hemispherically-capped rod-to-plane gaps positioned in air are investigated. The onset voltage is calculated based on the self-recurring single electron avalanche developed in the investigated gap. Accurate calculation of the electric field in the vicinity of a coated rod and its correlation to the field values near a bare rod of the same radius are obtained using the charge simulation method. The calculated field values are utilized in evaluating the onset voltage of the corona. Also, laboratory measurements of the onset voltage on bare and coated electrodes are carried out. The effects of varying the field nonuniformity, the coating thickness and its permittivity on the onset voltage values are investigated.
The results show that coating the electrodes with a dielectric material is effective in increasing the onset voltage of the corona on its surface. The calculated onset voltage values for coated and bare electrodes agree satisfactorily with those measured experimentally.