| publication name | “Ductility of Biaxially Loaded High Strength Reinforced Concrete Columns”, Journal of Engineering and Applied Science, Cairo University, Egypt, Vol. 48, No. 4, pp. 655-674. |
|---|---|
| Authors | Torky, A. and Shaaban, I. G., |
| year | 2001 |
| keywords | Biaxial columns; HSC; design formula; reinforcement ratio; ratio of load eccentricity |
| journal | Journal of Engineering and Applied Science, Cairo University |
| volume | 48 |
| issue | 4 |
| pages | 655-674 |
| publisher | Cairo University |
| Local/International | Local |
| Paper Link | Not Available |
| Full paper | download |
| Supplementary materials | Not Available |
Abstract
Eight reinforced High Strength Concrete “HSC” columns of dimensions 150 x 150 x 1200 mm were cast, tested and studied for both strength and deformational behavior. The investigated parameters included ratio of load eccentricity in both x and y directions, tie reinforcement ratio and configuration, and vertical steel percentage. Within the limits of the test results of this study, it was found that increasing load eccentricity resulted in reducing the ultimate capacity of the studied HSC columns by approximately 15%. In addition, increasing the lateral confinement lead to an increase of ultimate capacity by approximately 22%. Moreover, tie configuration was more effective than ties reinforcement ratio on the ductility of studied HSC columns. Increasing vertical steel percentage lead to an improvement of ductility of HSC columns. A proposed design formula was developed for predicting the capacity of eccentric and biaxially loaded HSC columns.