Behavior of Eccentrically Loaded Plain and Steel Fiber Reinforced Concrete Filled Steel Box Columns
Jurnal Teknologi • 2013
معلومات البحث
المؤلفون
Hanan Hussien Eltobgy, Ibrahim Galal Shaabana, Salah Eldin Abdullah
الكلمات المفتاحية
Composite columns; steel tube; finite element; steel fibers; slenderness ratio
المجلة العلمية
Jurnal Teknologi
الناشر
Penerbit UTM Press
المجلد
61:3
العدد
15 March 2013
الصفحات
79-85
publication.type
International
رابط البحث
Not Available
المواد المرفقة
Not Available
الملخص
The present study investigates the behavior of steel fiber reinforced concrete filled steel box columns
(SFRCFSBC) targeting to enhance their strength. A nonlinear finite element model using ANSYS
program has been developed to investigate the structural behavior of the inspected columns. The results
obtained from that model has been compared with those calculated using Euro code (EC4), AISC/LRFD
(2005) and the Egyptian Code of Practice for Steel Construction (ECPSC/LRFD 2007). The comparison
indicated that the results of the model have been evaluated to an acceptable limit of accuracy. A
parametric study was carried out to investigate the effect of wall thickness, column slenderness and
percentage of steel fiber in concrete on the ultimate strength of composite columns. Confinement of the
concrete core provided by the steel case was also investigated. It can be concluded from the results that a
considerable increase in compressive and flexural strength may be gained by increasing the steel fiber
percentage up to 4%. The highest rate of increase in strength for long columns was about 20% by using
steel fiber percentage between 0.5% and 1.0%, while for short and medium columns was about 10% by
using steel fiber percentage between 1% and 2%
(SFRCFSBC) targeting to enhance their strength. A nonlinear finite element model using ANSYS
program has been developed to investigate the structural behavior of the inspected columns. The results
obtained from that model has been compared with those calculated using Euro code (EC4), AISC/LRFD
(2005) and the Egyptian Code of Practice for Steel Construction (ECPSC/LRFD 2007). The comparison
indicated that the results of the model have been evaluated to an acceptable limit of accuracy. A
parametric study was carried out to investigate the effect of wall thickness, column slenderness and
percentage of steel fiber in concrete on the ultimate strength of composite columns. Confinement of the
concrete core provided by the steel case was also investigated. It can be concluded from the results that a
considerable increase in compressive and flexural strength may be gained by increasing the steel fiber
percentage up to 4%. The highest rate of increase in strength for long columns was about 20% by using
steel fiber percentage between 0.5% and 1.0%, while for short and medium columns was about 10% by
using steel fiber percentage between 1% and 2%
أعضاء هيئة التدريس - جامعة بنها