Detrusor Blood Flow as a Measurement of Bladder Outlet Obstruction in Patients with Benign Prostatic Hyperplasia
• 2006
معلومات البحث
المؤلفون
Tarek El Karamany, Tohamy Al Kholi,Ibrahim Hafez, Ahmed M Al-Adl, Ashraf Abdel Aal
الكلمات المفتاحية
Not Available
المجلة العلمية
Not Available
الناشر
Not Available
المجلد
Not Available
العدد
Not Available
الصفحات
Not Available
publication.type
Local
رابط البحث
Not Available
المواد المرفقة
Not Available
الملخص
Abstract:
In patients with benign prostatic hyperplasia (BPH), detrusor blood flow was evaluated by color Doppler ultrasonography (CDU) with the aim of revealing its possible usefulness as a measure of bladder outlet obstruction (BOO).
Material and Methods:
A total of 30 men with lower urinary tract symptoms (LUTS) suggestive of BPH underwent pressure flow study (PFS) and detrusor CDU. Pulsatile blood flow was measured at three sites, the anterior bladder wall and the two lateral walls, and detrusor resistive index (DRI) was calculated. The findings were compared between patients with and without BOO.
Results:
Between patients with and without BOO, there were significant differences for age (69.2 vs. 62.1 years P <0.005), PSA (3.9 vs. 2.6 ng/ml, P <0.05), prostate volume (45.5 vs.34.7 ml, P <0.05), bladder wall thickness (5.6 vs. 3.2 mm, P <0.001), blood flow detection (16/8 vs. 3/12, P <0.001). BOO was detected with diagnostic accuracy of 83.3% (25/30) by CDU.
Conclusion:
Color Doppler ultrasonography has the promise to become a possible indicator for the diagnosis of BOO. To ascertain its clinical utility in terms of BOO predictability, a prospective study in a large cohort is needed.
In patients with benign prostatic hyperplasia (BPH), detrusor blood flow was evaluated by color Doppler ultrasonography (CDU) with the aim of revealing its possible usefulness as a measure of bladder outlet obstruction (BOO).
Material and Methods:
A total of 30 men with lower urinary tract symptoms (LUTS) suggestive of BPH underwent pressure flow study (PFS) and detrusor CDU. Pulsatile blood flow was measured at three sites, the anterior bladder wall and the two lateral walls, and detrusor resistive index (DRI) was calculated. The findings were compared between patients with and without BOO.
Results:
Between patients with and without BOO, there were significant differences for age (69.2 vs. 62.1 years P <0.005), PSA (3.9 vs. 2.6 ng/ml, P <0.05), prostate volume (45.5 vs.34.7 ml, P <0.05), bladder wall thickness (5.6 vs. 3.2 mm, P <0.001), blood flow detection (16/8 vs. 3/12, P <0.001). BOO was detected with diagnostic accuracy of 83.3% (25/30) by CDU.
Conclusion:
Color Doppler ultrasonography has the promise to become a possible indicator for the diagnosis of BOO. To ascertain its clinical utility in terms of BOO predictability, a prospective study in a large cohort is needed.
أعضاء هيئة التدريس - جامعة بنها