Banner

Percutaneous Screw Fixation of Acetabular Fractures

• 2021
Back
Publication Information
Authors Hassan ElsakaMohamed El-ashhabMamdouh El KaramanyAbdelsamie M. HalawaAbdelsamie M. Halawa
Keywords Not Available
Journal Not Available
Publisher Not Available
Volume Not Available
Issue Not Available
Pages Not Available
publication.type Local
Paper Link Open Link
Supplementary Materials Not Available
Abstract
Aims: To investigate the use of PCS fixation for acetabular fractures including indications, preoperative planning, operative technique, and complications during the study period.
Setting and design; Retrospectively we used PCS for fixations of several types of acetabular fractures either nondisplaced, minimally displaced guided by fluoroscopy.
Patients and methods; The study included 20 patients after obtaining informed consent who underwent acetabular fixation by anterior column, posterior column, supra-acetabular screws, combination of all and combination of plate and screw between June 2015 and June 2018.
Statistical analysis used: The software for statistical package for social sciences for windows 10 was used for all statistical calculations. Each variable was tested for its normal value using the Mann-Whitney Test and exact P values were calculated. Significance was set at the P value of less than 0.05 level.
Results; All cases had good to excellent functional results according to the modified Merle d’Aubigné Hip Score. We managed to mobilize all patients out of bed from the 2nd day of surgery and to avoid a 2nd approach for transverse fractures by the screw.
Conclusion: Our results show that PCS under fluoroscopic control is a safe technique to treat some pattern of acetabular fractures and with some tips and tricks surgical and fluoroscopy time can be minimized.