Banner

Enhanced Discharge of ANG storage for vehicle use

• 2009
Back
Publication Information
Authors Usama Mohamed Nour, Aghreed M. Tayeb, Hassan A Farag, SherineAwad
Keywords Not Available
Journal Not Available
Publisher Not Available
Volume Not Available
Issue Not Available
Pages Not Available
publication.type International
Paper Link Open Link
Supplementary Materials Not Available
Abstract
Discharging the ANG storage tank from 3.5 MPa to a depletion pressure results in temperature fall within the
ANG vessel. The fall of storage pressure was from a rapid to
slow rate along with constant rate of gas removal while the
temperature was falling drastically with depressurization as a
result of heat of desorption and partly due to pressure drop. In the present study the characteristics of ANG storage system during discharge has been studied. When gas was discharged at discharge rate 1, 5, 10 l/min, a much drop in bed temperature occurred. Bed Preheating was investigated as a solution to enhance the discharge process and to avoid much amount of gas retained (not desorbed). Improvement in the amount desorbed and capacity was recorded as a result.