“Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution Substations during Working Conditions”, TELKOMNIKA Indonesian Journal of Electrical Engineering, Vol. 12, No. 9, September 2014.
TELKOMNIKA Indonesian Journal of Electrical Engineering • 2014
Publication Information
Authors
Sayed A. Ward, Samy M. Ghania , E. M. Shaalan,
Keywords
electric field distribution, 500/220 kV substation,
Journal
TELKOMNIKA Indonesian Journal of Electrical Engineering
Publisher
TELKOMNIKA Indonesian Journal of Electrical Engineering
Volume
Vol. 12, No. 9, September 2014, pp. 6471 ~ 6478
Issue
Vol. 12, No. 9, September 2014, pp. 6471 ~ 6478
Pages
Vol. 12, No. 9, September 2014, pp. 6471 ~ 6478
publication.type
International
Paper Link
Not Available
Supplementary Materials
Not Available
Abstract
The high level electric field intensity produced by high voltage (HV) equipments inside 500/220kV
substations is harmful for the human (staff) health. Therefore the minimum health and safety requirements
regarding the exposure of workers to the risk arising from electric fields produced inside these substations
is still considered as a competitive topic for utility designers, world health organization (WHO) and
biomedical field researchers. It is very important to have knowledge about levels distribution of electric field
intensity within these high voltage substations as early stage in the process of substation design. This
paper presents results of investigation 50Hz electric field intensity distribution inside 500/220kV power
transmission substations in Cairo, Egypt. This paper presents a method for assessment the distribution of
50HZ electric field intensity distribution inside this substation, this method of analysis is based on the
charge simulation technique (CSM). This study will serve for planning service works or for inspection of
equipment on HV power transmission substations.
substations is harmful for the human (staff) health. Therefore the minimum health and safety requirements
regarding the exposure of workers to the risk arising from electric fields produced inside these substations
is still considered as a competitive topic for utility designers, world health organization (WHO) and
biomedical field researchers. It is very important to have knowledge about levels distribution of electric field
intensity within these high voltage substations as early stage in the process of substation design. This
paper presents results of investigation 50Hz electric field intensity distribution inside 500/220kV power
transmission substations in Cairo, Egypt. This paper presents a method for assessment the distribution of
50HZ electric field intensity distribution inside this substation, this method of analysis is based on the
charge simulation technique (CSM). This study will serve for planning service works or for inspection of
equipment on HV power transmission substations.
Staff Members - Benha University