Banner

Experimental investigation of vapor chamber with different working fluids at different charge ratios

Ain Shams Engineering Journal • 2012
Back
Publication Information
Authors Ahmed A.A. Attia *, Baiumy T.A. El-Assal
Keywords Vapor chamber; Flat heat pipe; Electronic cooling; Heat pipe
Journal Ain Shams Engineering Journal
Publisher Not Available
Volume Not Available
Issue Not Available
Pages Not Available
publication.type International
Paper Link Not Available
Supplementary Materials Not Available
Abstract
Vapor chamber is one of highly effective thermally spread techniques in electronic cooling.
In the following a work is conducted to evaluate thermal performance of 2.0 mm high and
50 mm diameter vapor chamber with water and methyl alcohol at different charge ratios. Also, a
solution of water and Propylene Glycol at two concentration 50%, 15% were tested to study the
effect of using surfactant as enhancement agent for working fluid. Also total thermal resistance
of the chamber is divided into three types (junction resistance, internal resistance, and condenser
resistance) to investigate and determine which type of thermal resistance has a major effect on
chamber total thermal resistance.