Banner

Effect of Mechanical Ventilation on Controlling Fire in Closed Room

• 2012
العودة
معلومات البحث
المؤلفون May Salama, Magi Kandil, Samia Rashad
الكلمات المفتاحية Not Available
المجلة العلمية Not Available
الناشر Not Available
المجلد Not Available
العدد Not Available
الصفحات Not Available
publication.type Local
رابط البحث Not Available
المواد المرفقة Not Available
الملخص
The work models and simulates fire growth in a
closed room. It examines the effect of various airflow rates of
mechanical ventilation on wall and ceiling temperatures, Heat
Release Rate, oxygen and carbon dioxide rates when
smoke/fire is detected. The objective of the simulation is to
find a way to control the temperature, fire growth and gas
rates in the room until fire fighters have control of the
situation. The model assumes that the ventilators are
continuously operating. The results of the simulation show that
there is a certain airflow rate for the mechanical ventilators
that achieves the goal, thus avoiding fire breakout. The
modeling and simulation is carried by CFAST which is a zone
model tool for fire modeling and simulation.