Banner

Strength of HSC Slender Columns - A Method of Analysis

• 2016
العودة
معلومات البحث
المؤلفون M. Abdel-Karim, G.T. Abdel-Rahman, I.G. Shaaban, M-Said
الكلمات المفتاحية Not Available
المجلة العلمية Not Available
الناشر Not Available
المجلد Not Available
العدد Not Available
الصفحات Not Available
publication.type International
رابط البحث Not Available
المواد المرفقة Not Available
الملخص
A method is presented for the strength analysis of HSC columns subjected to eccentric loading. The method is based on a stability analysis of pin-ended columns using the exact sinusoidal equation for the deflected shape of the column. The degradation in the column stiffness as the load increases, representing the basic characteristic of inelastic response of columns, is considered subject to equilibrium conditions, compatibility requirements, and constitutive relationships for the concrete and reinforcement. The tension stiffening effect was taking into consideration. The column integrity is limited by either material or instability mode of failure. The method was applied to a wide range of experimental data. The predicted ultimate behavior shows excellent correlation with the test results. The mean of the predicted-to-experimental ultimate load ratio was 0.94, with a coefficient of variation of 10.8%.