Evaluation of Vaginal Fluid Urea and Creatinine as Biomarkers of Preterm Premature Rupture of Membranes
• 2021
معلومات البحث
المؤلفون
Khaled M. slama, Ahmed Salah El din, Aymen S. Elgohary, Basma M. Mostafa
الكلمات المفتاحية
Not Available
المجلة العلمية
Not Available
الناشر
Not Available
المجلد
Not Available
العدد
Not Available
الصفحات
Not Available
publication.type
Local
رابط البحث
Not Available
المواد المرفقة
Not Available
الملخص
Background: PROMs occurs in 10% of all term pregnancies and
about 2- 4% of preterm pregnancies and is associated with
complications such as infection and preterm birth. Vaginal fluid
urea and creatinine levels may be helpful in the diagnosis of
PROM. Objectives: To evaluate the reliability of vaginal
washing fluid urea and creatinine as biomarkers for diagnosis of
preterm PROM. Subjects and Methods:A prospective case control study was conducted at the Obstetrics and Gynecology
Department; Benha University Hospital during the period from
September 2018 to September 2019. The study included 100
cases: 50 inpatient cases with preterm PROM and 50 cases from
those attending outpatient clinics for routine antenatal care. All
patients underwent speculum examination, nitrazine paper test,
and U/S. Results: The creatinine levels were 0.35 ±0.12 mg/dl
and 0.16± 0.08 mg/dl in confirmed cases and controls,
respectively. The urea levels were 6.5 ±2.48 mg/dl and 3.4 ±1.68
mg/dl in confirmed cases and controls, respectively. There was a
highly significant difference regarding creatinine level and urea level (P < 0.001). Sensitivity,
specificity, PPV and NPV for creatinine level were 100%, 84%, 86,2% and 100%, respectively.
Sensitivity, specificity, PPV and NPV, for urea level was 100%, 80%, 83.3% and 100%,
respectively, with a cut-off value of 0.2 mg/dl for creatinine level and 3 mg/dl for urea level.
Conclusions: Detection of vaginal fluid urea and creatinine to diagnose PROM is a simple,
reliable and rapid test with high sensitivity, specificity, PPV, NPV.
about 2- 4% of preterm pregnancies and is associated with
complications such as infection and preterm birth. Vaginal fluid
urea and creatinine levels may be helpful in the diagnosis of
PROM. Objectives: To evaluate the reliability of vaginal
washing fluid urea and creatinine as biomarkers for diagnosis of
preterm PROM. Subjects and Methods:A prospective case control study was conducted at the Obstetrics and Gynecology
Department; Benha University Hospital during the period from
September 2018 to September 2019. The study included 100
cases: 50 inpatient cases with preterm PROM and 50 cases from
those attending outpatient clinics for routine antenatal care. All
patients underwent speculum examination, nitrazine paper test,
and U/S. Results: The creatinine levels were 0.35 ±0.12 mg/dl
and 0.16± 0.08 mg/dl in confirmed cases and controls,
respectively. The urea levels were 6.5 ±2.48 mg/dl and 3.4 ±1.68
mg/dl in confirmed cases and controls, respectively. There was a
highly significant difference regarding creatinine level and urea level (P < 0.001). Sensitivity,
specificity, PPV and NPV for creatinine level were 100%, 84%, 86,2% and 100%, respectively.
Sensitivity, specificity, PPV and NPV, for urea level was 100%, 80%, 83.3% and 100%,
respectively, with a cut-off value of 0.2 mg/dl for creatinine level and 3 mg/dl for urea level.
Conclusions: Detection of vaginal fluid urea and creatinine to diagnose PROM is a simple,
reliable and rapid test with high sensitivity, specificity, PPV, NPV.
أعضاء هيئة التدريس - جامعة بنها