Utilization of a plasticized PVC optical sensor for the selective and efficient detection of cobalt(II)in environmental samples
Rsc. adv. • 2022
معلومات البحث
المؤلفون
Hesham H. El-Feky, Alaa S. Amin and Eslam M. I. Moustafa
الكلمات المفتاحية
Not Available
المجلة العلمية
Rsc. adv.
الناشر
royal society of chemistry
المجلد
12
العدد
Not Available
الصفحات
18431–18440
publication.type
International
رابط البحث
Open Link
المواد المرفقة
Not Available
الملخص
A novel sensitive, selective, and reversible cobalt(II) ion optical sensor was prepared by the incorporation of
5-[o-carboxyphenylazo]2,4-dihydroxybenzoic acid [CPDB] and sodium tetraphenylborate (NaTPB) in
a plasticized polyvinyl chloride (PVC) membrane containing dioctyl adipate (DOA) as a plasticizer. The
influence of several parameters such as pH, base matrix, solvent mediator and reagent concentration
was optimized. A comparison of the obtained results with those of previously reported sensors revealed
that the proposed method, in addition to being fast and simple, provided a good linear range (0.05–
45.20 mM) and low detection limit (0.015 mM). Low detection and quantification limits and excellent
selectivity in the presence of interfering ions such as Fe
3+
,Cu
2+
,Ni
2+
,Ag
+
,Au
3+
,Cr
,
and SO
4
2
make it feasible to monitor Co
2+
ion content accurately and repeatedly in environmental
samples with complicated matrices. The optode was regenerated successfully using 0.3 M nitric acid
(HNO
) solution while its response was reversible with a relative standard deviation (RSD) lower than 1.9%
for seven replicate determinations of 20 mMCo
3
2+
in various membranes. The optode was stable and was
stored for at least 15 days without observing any change in its sensitivity.
5-[o-carboxyphenylazo]2,4-dihydroxybenzoic acid [CPDB] and sodium tetraphenylborate (NaTPB) in
a plasticized polyvinyl chloride (PVC) membrane containing dioctyl adipate (DOA) as a plasticizer. The
influence of several parameters such as pH, base matrix, solvent mediator and reagent concentration
was optimized. A comparison of the obtained results with those of previously reported sensors revealed
that the proposed method, in addition to being fast and simple, provided a good linear range (0.05–
45.20 mM) and low detection limit (0.015 mM). Low detection and quantification limits and excellent
selectivity in the presence of interfering ions such as Fe
3+
,Cu
2+
,Ni
2+
,Ag
+
,Au
3+
,Cr
,
and SO
4
2
make it feasible to monitor Co
2+
ion content accurately and repeatedly in environmental
samples with complicated matrices. The optode was regenerated successfully using 0.3 M nitric acid
(HNO
) solution while its response was reversible with a relative standard deviation (RSD) lower than 1.9%
for seven replicate determinations of 20 mMCo
3
2+
in various membranes. The optode was stable and was
stored for at least 15 days without observing any change in its sensitivity.