The Short-Term Effect of Stent Size and Number on Left Ventricular Systolic Function Improvement After Elective Percutaneous Coronary Intervention
• 2020
معلومات البحث
المؤلفون
Shiamaa Mostafa*, Osama Sanad, Mahmoud Shawky,
Mohamed Magdy, Eman Elkeshk
الكلمات المفتاحية
Not Available
المجلة العلمية
Not Available
الناشر
Not Available
المجلد
Not Available
العدد
Not Available
الصفحات
Not Available
publication.type
Local
رابط البحث
Not Available
المواد المرفقة
Not Available
الملخص
Background. The effect of stent size and number on left ventricular systolic function improvement after percutaneous
coronary intervention (PCI) using drug eluting stent is not clear enough.
Aim. To study short-term effect of stent size and number on left ventricular systolic function improvement after
elective PCI.
Material and methods. The study included 150 adult patients with electively stented left anterior descending artery
lesion with drug-eluting stent. Patients were examined before PCI and 1 and 3 months after PCI using speckle tracking
echocardiography.
Results. Before revascularization, mean left ventricular ejection fraction was 51.2%±5.7, mean global longitudinal
peak systolic strain (GLPSS) – -9.29±0.94%. One month after PCI, mean GLPSS increased significantly to -14.05±1.72%
(p
coronary intervention (PCI) using drug eluting stent is not clear enough.
Aim. To study short-term effect of stent size and number on left ventricular systolic function improvement after
elective PCI.
Material and methods. The study included 150 adult patients with electively stented left anterior descending artery
lesion with drug-eluting stent. Patients were examined before PCI and 1 and 3 months after PCI using speckle tracking
echocardiography.
Results. Before revascularization, mean left ventricular ejection fraction was 51.2%±5.7, mean global longitudinal
peak systolic strain (GLPSS) – -9.29±0.94%. One month after PCI, mean GLPSS increased significantly to -14.05±1.72%
(p